FLYLINE MODULAR DIGITAL HIGH & LOW VOLTAGE PROTECTOR

FLYLINE VOLTAGE PROTECTOR DEVICE   

Flyline Modular digital Over & Under Voltage Protector (FDP) is saft guarding all costly home appliances,cctv,security alarm systems,laboratory equipments,computer etcc from lightening and voltage variations due to natural calamities .FDP is an advanced device with latest German Thecnology.Voltage variation in power supply will cause damage to our home appliances.FDP is protcting all appliances from voltage cut off ,low voltage cut off and time delay can be set.All these functions user can set and self healing.The electrical protecting equipments available in the markethas defects like no outstanding ,the system will not work if earthing is not prpoer and once it is off .we have toput it on manually.FDP is switching "off" and switching on automatically.Even if you are not in the house the FDP is aking care of all appliances,cctv security alarm system etc.FDP is an iedal equipment for located houses of NRI's.The FDP will act if the following ooccurs

1.Phase sequence disorder
2.Phase unbalance
3. of neutral line.
4.Breakage of any line level.
5.Over under voltage is any phase line.
FDP can be fixed in main distribution board easily

TECHNICAL SPECIFICATION OF SINGLE PHASE FLYLINE MODULAR DIGITAL OVER & UNDER VOLTAGE PROTECTOR

►Rated Power Supply : AC220V 50Hz Operating Voltage: 100-400 V (avoid burning out of electrical appliances under 380 voltage)►Passing Max. Current : 32A,63A. ►Max. Loading Power in Single Phase :7KVA,14KVA ►Over-voltage Action Cut-off Value : AC260±5V, action 0.01second action delay. Recovered Value : AC260±5V. (230-270V adjustable ►Under-voltage Cut-off Value : AC180±5V,0.1 seconds’ action delay. Recovered Value : AC195±5V.(120-210V adjustable).►Time Delay: Start time for First Connection: 15 Second. Delay time is free to set from 5 to 600 seconds after the first time.►Rapid action: The power disconnects the appliances with in 1 sec.►Self Power Consumption : ≤ 3W.►Dimensions : 84x52x75(LxWxH

TECHNICAL SPECIFICATION OF FLYLINE MODULAR DIGITAL OVER & UNDER VOLTAGE PROTECTOR

Specification:

1. Rated Power Supply : AC220V 50Hz Operating Voltage: 100-400 V (avoid burning out of electrical appliances under 380 voltage )
2. Passing Max.Current:20A,32A,40A,50A,60A.
3. Max. Loading Power: 4.4KVA, 7KVA, 8.8KVA, 11KVA, 13KVA
4. Over-voltage Action Cut-off Value : AC260±5V, action 0.01second action delay. Recovered Value : AC260±5V. (230-270V adjustable)
5. Under-voltage Cut-off Value : AC180±5V,0.1 seconds’ action delay. Recovered Value : AC195±5V.(120-210V adjustable).
6. Time Delay: Start time for First Connection: 15 Second. Delay time is free to set from 5 to 600 seconds after the first time.
7. Rapid action: The power disconnects the appliances with in 1 sec.
8. Self Power Consumption : ≤ 3W.
9. Dimensions : 84x52x75(LxWxH)

Model FDP-1
Number of Poled 1 P
Rated Voltage (V)AC 220
Rated Current (A) 32         |          63
Loading Power (KVA) 7 KVA         |          14 KVA
Over-Voltage Cut-Off Value(VAC) 230-270         adjustable ( 400 V short time)
Time Delay(s) 0.01 seconds
Under-Voltage Cut-Off Value(VAC) 120-210         adjustable
Time Delay(s) 0.1 seconds
Dimensions 84*52*75(L*W*H)
Self Power Consumption(W) ≤ 3w
Ambient Temperature (C ) -20-+40

instruction for use:1 Phase

1.This button : for displaying the voltage (3 phase or 1 phase )Press the button for 10s to switch to single phase voltage indicating.
2.The second button : :delay time setting.Press the button for 10s until the decimal point flashes.Then press button "+"or "-" to set the delay time(5-600s)
3.The third button under voltage value setting. Press the button for 10s then the decimal point of digital panel flashes. Then press “ + ” or “ - ”to set the voltage (120-210V)
4.The fifth button : over voltage value setting. Press the button for 10s, then the decimal point on digital panel will flash. The press “ + ” or “ – ”to set the voltage ( 230-270V)

The Protector will act if the following occurs

►Sequence disorder.►Phase unbalance.►Breakage of neutral line.►Breakage of any live line.►Over-voltage of any phase.►Under-Voltage of any phase.

TECHNICAL SPECIFICATION OF Three Phase Flyline Modular Digital Over & Under Voltage Protector :

Model FDP-3
Number of Poled 3 P
Rated Voltage (V)AC 220
Rated Current (A) 32         |          63
Loading Power (KVA) 20 KVA         |          40 KVA
Over-Voltage Cut-Off Value(VAC) 230-270         adjustable
Time Delay(s) 0.01 seconds
Under-Voltage Cut-Off Value(VAC) 120-210         adjustable
Time Delay(s) 0.1 seconds
Dimensions 85*90*75(L*W*H)
Self Power Consumption(W) ≤ 3W
Ambient Temperature (C ) -20-+40

conditions of use

►Relative humidity:≤85%.►Latitude:≤2000m.►No corrosive gas or conductive dust.►Instalation :Vertical mounting on DIN rail

Precautions:line of neutral of this product does not have function of isolating.Please cut offm isolating switch before operation

instruction for use:3 Phase

1.This button : for displaying the voltage (3 phase or 1 phase )Press the button for 10s to switch to single phase voltage indicating.
2. The second button : :delay time setting.Press the button for 10s until the decimal point flashes.Then press button "+"or "-" to set the delay time(5-600s)
3. The third button under voltage value setting. Press the button for 10s then the decimal point of digital panel flashes. Then press “ + ” or “ - ”to set the voltage (120-210V)
4. The fifth button : over voltage value setting. Press the button for 10s, then the decimal point on digital panel will flash. The press “ + ” or “ – ”to set the voltage ( 230-270V)

press the forth button ,the last time fault voltage will be displayed in 2 seconds .The lights indicate the fault phase

Fault Indication

1.Wire Connection Error
Flashing letters CBA on the board indicates phase sequence error .Change connecting sequence of the live lines to solve this problem.(if OPO appears first and then CBA flashes.Please check if the neutral line and live line where reversely connected.)
2.Phase Loss
OPO :Lack of neutral line.►:OPA : Lack of Phase A live line.►:OPB Lack of Phase B live line.►:OPC Lack of Phase C live line
The display board is not lighted:lack of 2 or 3 phases of live lines

3.Phase Imbalance:H-L appears when voltage difference between any two phases is over 35%(>77V)

4.Over Or Under Voltage Protection :H and L on the left ,center and rigt of the indicating board stand for over voltage and under voltage of phase A ,B and C respectively.




        

        

MORE FLYLINE ELECTRIC PROTECTOR VIDEOS :-CLICK HERE


Products short informative videos :-Click here

Products detailed informative videos :-Click here

Useful Technical informative video :-Click here

      

Flyline solar Hybrid system:-Click here

Flyline solar standalone system:-Click here

Flyline solar On grid system:-Click here

MG solar water heater videos :-Click here

Flyline Solar Streetlight videos :-Click here

MG Mobile mortuary videos :-Click here

MG Mortuary chamber videos :-Click here

Murickens Business Promotional & Social service videos :-Click here

Flyline Solar Battery Specifications and details :-Click Here

Flyline Solar Standalone Inverter Picture :  Click

GREEN ENERGY PROMOTION VIDEOS BY MG GROUP:-  Click Here

ENQUIRY
Watts of some electronic products we use Click Here

Flyline Solar power plant installation video of murickens:  Click Here

        

Murickes BrouchureClick Here


ALL THE PRODUCT MARKETED BY

MURICKENS GROUP

CORPORATE OFFICE. KADUTHURUTHY,KOTTAYAM,KERALA, INDIA.

MOB: 8281848484, 9188323232

09447366779 , 09446822522

E-MAIL: MURICKANS@GMAIL.COM, MG@MURICKENS.COM

OUR DIRECT BRANCH OFFICES AT: ERNAKULAM - PALARIVATTAM

KOTTAYAM - MANIPPUZHA

CHENGANNUR - KALLISSERY

AND REPRESENTATIVE OFFICIALS AT

BOMBAY AND USA